![]() It is done by filling up the volume of Zahn Cup with the required liquid, and then used a index finger to stop any flow out of the liquid. A ring at the Zahn Cup handle allows the cup to be hanged perpendicularly(still with the finger stopping any liquid flow out).Prepare a Digital stopwatch and set zero. Immediately start the stopwatch when the finger is released. As soon as there is a first “break” of the flow, stop the stopwatch. The second shown is the time of the liquid flow, which is also the flow viscosity of that liquid.You can convert S90/Zahn Signature Dip Cup readings to ASTM D 4212. ![]() This test method is recommended for viscosity control work within one plant or laboratory and should be used to check compliance with specifications only when sufficient controls have been. Its orifice diameters adjusted at the factory for appropriate results with applicable NIST traceable Newtonian oils. Only use CALIBRATED cups with a GARDCO (Paul N. 1.1 This test method covers the determination of viscosity of paints, varnishes, lacquers, inks, and related liquid materials by dip-type viscosity cups. Each cup has a 12-inch loop handle to allow the cup to be dipped by hand into a liquid container. At the center of this handle is a finger-ring for holding the cup in a vertical position during use.NT 102 Zahn Cups can be used to quickly measure the viscosity of liquids such as Paint, Ink, Varnishes, Syrup and Oil. It is produced according with ASTM D 816, ASTM D 1084,ASM D 4212.The Stainless Steel Cups are molded precisely and the orifices are precision drilled using high-speed CNC drilling.This test method is recommended for viscosity control work within one plant or laboratory and should be used to check compliance. This test method covers the determination of viscosity of paints, varnishes, lacquers, inks, and related liquid materials by dip-type viscosity cups. Type: made of stainless steel, with fixed stainless steel nozzle, orifice No. ASTM D1474/D1474M-13 (2023) Priced From 57.00. Type: made of stainless steel, with fixed stainless steel nozzle, orifice No. Viscosity by Dip-Type Viscosity Cups 1 This test method is under the jurisdiction of ASTM Committee D-1 on Paint and Related Coatings, Materials, and. Type: made of stainless steel, with fixed stainless steel nozzle, orifice No. Type: made of stainless steel, with fixed stainless steel nozzle, orifice No. Obsnap Instruments Sdn Bhd - TQC sheen - Viscosity Cup ASTM D1084 D4212 Immersion Zahn Viscosity Flow Cups Coating / Paint Testing Malaysia, Selangor. Optional: possible to certify by calibration with certified oils centistokes Cup Number Equationsa Where t Time of Flow, s v Kinematic Viscosity, mm2/s Minimum Maximum Minimum Maximum Zahn cups (see ASTM D 4212) 1. The EZ Cup formula for each cup of the series matches the applicable ASTM formula in D4212 at the recommended calibration level. Type: made of stainless steel, with fixed stainless steel nozzle, orifice No. 3 Guaranteed Tolerance Complies with & Exceeds ASTM D4212 Oils used to standardize EZ Cups are produced in accordance with ISO/IEC 17025, ISO Guide 34, ISO 9001. TQC Viscosity Cup ASTM D1084 D4212 Immersion Zahn ASTM D 4212 : 2016 Standard Test Method for Viscosity by Dip-Type Please Wait. TQC viscosity cups are made under the continuing quality control procedures.Įach cup is provided with an engraved unique serial number. The design of the cup and orifice eliminate hard to clean recesses. Ideal for measuring coatings and other fluids during application or production.Įach cup has a long handle to allow the cup to be dipped by hand into a liquid container, which makes it easy to quickly check and adjust the viscosity of many different type of liquids. The TQC Viscosity Cup ASTM D1084 D4212 Immersion Zahn is a range of stainless steel (SS303) viscosity cups with fixed stainless steel inner cavity nozzle and handle. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |